Amplifier Unit NPN
Keyence AP-40Z
Separate Amplifier Type Pressure Sensor AP-40 series
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | AP-40Z | |
Type | Amplifier, NPN | |
Applicable sensor head | AP-41, AP-43, AP-44 | |
Rated pressure | -15% to +110% of F.S. | |
Display | 3 1/2-digit, 2-colour, 7-segment LED (Character height: 11 mm), Display cycle: 5 times/sec. | |
Display resolution | AP-41: 0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar AP-43: 0.001 MPa, 0.01 kgf/cm2, 0.2 Psi, 0.01 bar AP-44: 0.2 kPa, 2 mmHg, 0.1 inchHg, 0.002 bar | |
Display temperature characteristic | ±1.0 % max. of F.S. | |
Mounting | With supplied mounting bracket (2 types) or optional panel mounting bracket*1 | |
Response time (Chattering prevention function) | 2.5/5/100/500 msec | |
I/O | Zero-shift input | Input time: 20 ms or more |
Control output | NPN: 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C. selectable) | |
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple 10 % or less |
Current consumption | 105 mA (12 V), 55 mA (24 V) (including sensor head) | |
Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |
Shock resistance | 100 m/s2, 3 times in each of X, Y and Z axis | |
Material | Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, Cable: Oil-proof cabtyre cable | |
Weight | 80 g (including 2 m cable) (28 g without cable) | |
*1 Optional panel mounting brackets: OP-31357 (black), OP-32808 (gray) and OP-42192 (for a 5 mm-thick panel) |