Amplifier Unit, Expansion Unit, PNP
Keyence AP-V42AWP
Wire-saving AI Digital Pressure Sensor AP-V40 series
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | AP-V42AWP | |
Type | Amplifier Unit, PNP | |
Applicable sensor head | AP-41M, AP-41, AP-43, AP-44, AP-48 | |
Set and display range | -15 to +110 % of F.S.*1 | |
Display | 4 1/2-digit, 2-colour, 7-segment LED (Character height: 4.5 mm), AI indicator (green), Display cycle: 10 times/s | |
Operation indicator | Red LED x 2 (corresponding to control output 1 and 2) | |
Repeatability | ±0.2 % of F.S. | |
Display resolution | AP-41M/41: Standard mode 0.1 kPa, High-resolution/Focus mode 0.01 kPa AP-43: Standard mode 0.001 MPa, High-resolution/Focus mode 0.1 kPa AP-44/48: Standard mode 0.1 kPa, High-resolution/Focus mode 0.02 kPa | |
Power consumption | Normal | 12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
Display temperature characteristic | ±1 % of F.S. max. | |
Hysteresis | Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) | |
Response time (Chattering prevention function) | 1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) | |
I/O | Analogue output | - |
Zero-shift input | Input time: 2 ms or more (or analog output selectable) | |
Control output | PNP open collector 20 mA max. (at 30 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) | |
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Power consumption | Eco mode | 12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Polycarbonate | |
Accessories | End Unit?Head Connector, and Expansion seal | |
Weight | Approx. 80 g (with 2-m cable) | |
*1 The focus range applies while in focus mode only. |