PROFIBUS DP Compatible Communication Unit
				GET A PRICE
				
					
						
				
			
								
							To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.						
					
				Specification
				
					
						
							
						
					
				
			
								| Model | DL-PD1 | |
| Sensor connection specifications | Connectable sensors | Sensor amplifiers with D-bus support*1 | 
| Number of connectable sensor units | 15 units max.*2 | |
| PROFIBUS DP specifications | Device type | DP-V1 Slave (D-sub 9 pin, Number of the ports: 1) | 
| Communication speed | 9.6 kbit/s to 12 Mbit/s | |
| Cable length | 9.6 / 19.2 / 45.45 / 93.75 kbit/s : 1200 m 187.5 kbit/s : 1000 m 500 kbit/s : 400 m 1.5 Mbit/s : 200 m 3 / 6 / 12 Mbit/s : 100 m | |
| Power voltage | 20 to 30 VDC, including ripple (p-p) 10% (This voltage is supplied from the connected sensor amplifier.) | |
| Power consumption | 1600 mW or less (65 mA max. at 24 V) | |
| Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing) | 
| Relative humidity | 35 to 85 % RH (No condensation) | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
| Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
| Materials | Main unit case and dust cover: Polycarbonate PROFIBUS connector: Steel – Nickel plating | |
| Weight | Approx. 65 g | |
| *1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers. *2 Varies with the sensor amplifiers connected. | 
 
	 
	 
								 
								
 
	 
	 
	