Specification
Model | FS-N15CP | |
Type | 1 output type | |
Output | PNP | |
Input/Output configuration | M8 connector *1 | |
Main unit/Expansion unit | Main unit | |
Control output | 1 output PNP open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or less | |
External input | 1 input Input time 2 ms (ON)/20 ms (OFF) or more, when selecting External calibration 25 ms (ON/OFF) or more | |
Response time | 50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |
Multiple connections to Expansion units | 0 units (expansion not possible) | |
Output toggle | LIGHT-ON/DARK-ON (switch-selectable) | |
Light source | Red, 4-element LED (Wavelength: 630 nm) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | 0 units (connection not possible) | |
Case dimensions | H30.3mmxW9.8mmxL71.8mm | |
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current Consumption | Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V) *2 Eco on (ALL): 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V) *2 Eco full: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V) | |
Environmental resistance | Enclosure rating | IP66*3*4 |
Ambient light | Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less | |
Ambient temperature | -20 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Case material | Main unit: glass-reinforced PBT; Cover: Sulfonic resin | |
Material | Adapter | Glass-reinforced PBT |
Weight | Approx. 30 g | |
*1 Use a cable of 30 m or less. *2 When the Power Mode is set to HIGH SPEED, 100 mW (4.0 mA) will be added. *3 About the enclosure rating when a small-diameter fibre unit (the diameter of the cable is ø1.3 or ø1.0) is used. IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/93/43/63/63T etc.) is used. When any small-diameter fibre units except for the above are used, IP65 is applied. *4 In any of the following cases, the enclosure rating IP66/IP65 cannot be satisfied. When the Fibre Unit and KEYENCE's M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first.Then retighten it as much as 1/16-1/8 of a rotation with pliers.) When the Fibre Unit and KEYENCE's M8 connector cable are not connected When the dust cover of the Sensor Amplifier is open When there is debris in the dust cover When the waterproof adapter A/B are not used at the time of installation of a small-diameter fibre unit. |