Amplifier Unit, Panel Mount Type, PNP
Keyence GT-75AP
General Purpose Digital Contact Sensor GT series
Categories: Contact Distance Sensors / LVDT, Measurement Sensors
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | GT-75AP | |
Type | Amplifier unit | |
Mounting type | Panel mount | |
Output | PNP output | |
Main unit/Expansion unit | Main unit*1 | |
Power consumption | Normal | At 12 V: 1,140 mW (95 mA) or less, At 24 V: 1,200 mW (50 mA) or less |
Power saving (Eco) | At 12 V: 600 mW (50 mA) or less, At 24 V: 840 mW (35 mA) or less | |
Display power | Measured value display | 6-digit 7-segment LED (red) |
Other displays | 2-colour 13-level bar LED display (red, green), indicators (red, green) | |
Display range | -99.999 to 999.999 | |
Display resolution | 1 µm | |
Sampling rate | 2,000 times/second | |
Control input | Timing/preset/bank input | Timing input: Non-voltage input (relay contact, solid state), input time: 2 ms or more Preset/Bank input: Non-voltage input (relay contact, solid state), input time: 20 ms or more |
Response time | hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s | |
HIGH, GO, LOW output | PNP Offenkollektor, max. 50 mA (40 V oder weniger), Restspannung: 1 V oder weniger, N.O./N.C. umschaltbar | |
Major functions | Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks), Self-timing, Power save (eco) mode, Application mode, Calibration function, Core alarm | |
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less*2 |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing) |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC | |
Accessories | Panel mounting bracket, protective front cover, power cable, instruction manual | |
Weight | Approx. 110 g (: including panel mounting bracket, protective front cover, power cable) | |
*1 One main unit and nine expansion units (ten in total) can be additionally installed. For additional amplifier unit installation, each output current must be 20 mA or less. *2 If additional amplifier units are installed, the power supply voltage is 24 VDC. |