Sensor Head
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | IA-030 | |
Reference distance | 30 mm | |
Measurement range | 20 to 45 mm | |
Light source | Type | Red semiconductor laser, wavelength: 655 nm (visible light) |
Laser class | Class 1 (FDA (CDRH) Part1040.10)*1 Class 1 (IEC 60825-1) | |
Output | 220 µW | |
Spot diameter (at standard distance) | Approx. 200 x 750 µm | |
Linearity | ±0.1% of F.S. (F.S.=±5 mm, 25 to 35 mm)*2 | |
Repeatability | 2 µm*3 | |
Sampling cycle | 0.33/1/2/5 ms (4 levels available) | |
Operation status indicators | Laser warning: Green LED, Analogue output: Red LED, Measurement centre: Green LED | |
Temperature characteristics | 0.05% of F.S./°C (F.S.=±5 mm, 25 to 35 mm) | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent lamp: 5,000 lux*4 | |
Ambient temperature | -10 to +50 °C (No condensation or freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |
Material | Housing material: PBT Metal parts: SUS304 Packing: NBR Lens cover: Glass Cable: PVC | |
Weight | Approx. 120 g (including cable) | |
*1 The classification is implemented based on IEC 60825-1 following the requirement of Laser Notice No.50 of FDA (CDRH). *2 Value when measuring the KEYENCE standard target (white diffuse object). *3 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16. *4 Value when the sampling rate is set to 2 ms or 5 ms. |