Specification
Model | IB-01 | |
Light source | Wavelength | 660 nm (Visible light semiconductor laser) |
Laser Class | Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1) | |
Mounting distance | 0 to 2,000 mm | |
Measurement range | ø1 mm (Installation distance 0 to 300 mm) ø1 to 2.5 mm (Installation distance 300 to 2,000 mm) | |
Sampling cycle | 12,500 times/sec. (80 µs) | |
Minimum detectable object | ø8 µm (Installation distance 0 to 300 mm) ø8 to 50 µm (Installation distance 300 to 2,000 mm)*2 | |
Repeatability | 5 µm (distance 0 to 300 mm)*3 | |
Temperature characteristics | ±0.2 % of F.S./°C*4 | |
Operation indicator | Laser emission warning indicator: green LED | |
Environmental resistance | Ambient light | Incandescent lamp: 5,000 lux, Solar light: 10,000 lux |
Ambient temperature | 0 to +40 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |
Material | Case | PBT |
Lens cover | Glass | |
Cable | PVC (2 m) | |
Weight | Approx. 140 g | |
*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the centre of the measurement range. *3 When distance between transmitter and receiver is set to 300 mm, and light is half-shielded at a position 150 mm from receiver. Deflection width (±2?) when sampled for 30 seconds with an average number of times set to 64 times. *4 When distance between transmitter and receiver is set to 100 mm and full light is received. |