Amplifier Unit, Panel Mount Type
Keyence IB-1500
Laser Thrubeam Sensor IB series
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | IB-1500 | |
Type | Panel mount | |
Main unit/Expansion unit | Main unit | |
Head compatibility | Yes | |
Display | Display resolution | 0.01 %, 0.1 %, 1 % (switchable) |
Display range | –99.999 to 99.999, –99.99 to 99.99 –99.9 to 99.9, –99 to 99 (switchable) | |
Digital display method | Dual7-segmentdisplay Upper level: 2-color (green/red) 5 digits Lower level: 5 green digits | |
Operation indicator | Judgment indicator: 2-color (green/red) LED (HI, GO, LO) Bank indicator: Green LED x 4 Laser emission warning indicator: Green LED Others: Green LED x 8, red LED x 3 | |
Analogue output voltage | ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 ? *1 | |
Analogue current output | 4 to 20 mA Maximum load resistance 350 ? *1 | |
Control Input | Bank switch input, zero shift input | Non-voltage input *2 |
Control input | Zero-shift input | |
Laser emission stop input | ||
Timing input | ||
Reset input | ||
Adjust input | ||
Control output | Judgment output (check output) | Open collector (NPN/PNP switchable, N.O./N.C. switchable) *3 |
Power supply | Power consumption | 2550 mW or less (at 30 V, 85 mA max.) *4 *5 (including analog current output) |
Rating | Power voltage | 10 to 30 VDC, including ripple (P-P) 10% Class 2 or LPS *4 |
Environmental resistance | Pollution degree | 2 |
Ambient temperature | -10 to +50 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes | |
Material | Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC | |
Weight | Approx. 170 g (including accessories) | |
*1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected. *2 The four external input wires are assigned with desired inputs. Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less *3 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less *4 Use with the over current protection device which is rated 30 V or more and not more than 1 A. *5 Does not include the power consumption of the load. The power consumption with expansion units installed is the total of each amplifier unit’s power consumption. Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW |