Sensor heads
Keyence IL-030
CMOS Multi-Function Analogue Laser Sensor IL series
	
	
	Categories: Laser Displacement Sensors, Measurement Sensors
	
	
						
				GET A PRICE
				
					
						
				
			
								
							To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.						
					
				Specification
				
					
						
							
						
					
				
			
								| Model | IL-030 | |
| Reference distance | 30 mm | |
| Measurement range | 20 to 45 mm | |
| Light source | Type | Red semiconductor laser, wavelength: 655 nm (visible light) | 
| Laser class | Class 1 (FDA (CDRH) Part1040.10)*1 Class 1 (IEC 60825-1) | |
| Output | 220 µW | |
| Spot diameter (at standard distance) | Approx. 200 x 750 µm | |
| Linearity | ±0.1% of F.S. (25 mm to 35 mm)*2*3 | |
| Repeatability | 1 µm*4 | |
| Sampling rate | 0.33/1/2/5 ms (4 levels available) | |
| Operation status indicators | Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED | |
| Temperature characteristics | 0.05% of F.S./°C*3 | |
| Environmental resistance | Enclosure rating | IP67 | 
| Pollution degree | 3 | |
| Ambient light | Incandescent lamp: 5,000 lux*5 | |
| Ambient temperature | -10 to +50 °C (No condensation or freezing) | |
| Relative humidity | 35 to 85 % RH (No condensation) | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
| Material | Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC | |
| Weight | Approx. 60 g | |
| *1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50. *2 Value when measuring the KEYENCE standard target (white diffuse object). *3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm *4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. *5 Value when the sampling rate is set to 2 ms or 5 ms. | 
	
	
								
								