Specification
Model | IV-G15 | |
Type | Expansion unit | |
Tools | Type | Shape Detection, Area*1, Colour Area*2, position adjustment |
Number | Detection tools: 16 tools, position adjustment tool: 1 tool*3 | |
Switch settings (programs) | 32 programmes | |
Image history | Numbers | When using a colour type head: 100 images*4, when using a monochrome type head: 300 images*5*6 |
Condition | NG only/All is selectable*6 | |
Analysis information | OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs*7 | |
Other functions | HDR, HighGain, Colour filters*2, Digital zoom (2x, 4x)*8, Brightness correction, Tilt correction, White balance*2, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Total judgement result output, Direct connection (2 units or more), Failing sensor list, Failure hold | |
Indicators | PWR/ERR, OUT, TRIG, STATUS, LINK/ACT | |
Input | Type | Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) |
Inputs | 6 inputs (IN1 to IN6) | |
Function | IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input | |
Output | Type | Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower |
Outputs | 8 outputs (OUT1 to OUT8) | |
Function | Enable by assigning the optional functions Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool, Result of the logical operation of each tool, Main unit/expansion unit logical output | |
Ethernet | Standard | 100BASE-TX/10BASE-T*9 |
Connector | RJ-45 8pin connector*9 | |
Network function | FTP client, EtherNet/IPTM, PROFINET | |
Rating | Power voltage | Supplied from main unit |
Current consumption | 0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.) | |
Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing)*10 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Material | Main unit case: Polycarbonate | |
Weight | Approx. 150 g | |
*1 Monochrome type only *2 Colour type only *3 Tools can be installed by programmes. *4 When using the FTP client function: 70 pictures *5 When using the FTP client function: 210 pictures *6 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV/IV-G Series (IV-H1). *7 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV/IV-G Series (IV-H1). *8 Possible with both the colour type and monochrome type *9 This is for connection with the intelligent monitor (IV-M30) or software for the IV/IV-G Series (IV-H1). *10 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate. |