Description

Sensor Amplifier Main unit

GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model IX-1000
Main unit / expansion unit Main unit
Display Min. display unit 10 µm*1
Display range ±999.99 to ±999 mm (with 4 selectable steps)*1
Tools Scan mode Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2
Line mode Height (Ave./Max./Min.), Height difference (Ave./Max./Min.), Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2
Other functions Common ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgement conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security
Scan mode Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range
Line mode Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)
Input Input Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Number of inputs 8 (IN1 to IN8)
Function IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgement value only) Reset (judgement value and error)
Output Output Open collector output; NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less
Number of outputs 10 (OUT1 to OUT10)
Function Enable by assigning the optional functions Assignable functions: Total judgement result (All OK, Any OK/NG), run, busy, error, position adjustment result, tilt correction result, Monochromatic detection / Height detection tool result (OK/NG), Height / height difference / Max./Min. / calculation tool result (OK/NG/HIGH/LO), Alarm
Analogue voltage output ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 ?*3
Analogue current output 4 to 20 mA, max. load resistance: 350 ?*3
Number of programs 32
Statistical information Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1*4
Detection history Saved history 100*5
Save conditions Selectable from NG only / All*5
Ethernet Standard 100BASE-TX/10BASE-T*6
Connector RJ45 8-pin connector*6
Interface compatibility CC-Link / DeviceNetTM / EtherNet/IPTM / EtherCAT? / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*7
Number of connectible units Main units: 1, Expansion units: 1, Communication units (DL): 1
Ratings Power voltage 24 VDC ±10% (including ripple)
Current consumption Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *8
Environmental resistance Operating ambient temperature 0 to +50°C (No freezing)
Operating ambient humidity 35 to 85% RH (No condensation)
Material Main unit case: PC / Power connector: PA, POM / Analogue output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminium / Main unit rear DIN rail fixing tab: POM / Nameplate: PC
Weight Approx. 210 g
*1 For displaying on an IX Series control panel or PC software. *2 Configurable for each program. *3 Select ±5 V, 1 to 5 V, 0 to 5 V, or 4 to 20 mA for use. *4 When sample hold (edge), peak/bottom/P-P hold (level/edge) is set. *5 Saves to the sensor amplifier’s internal memory. Detection history saved inside the sensor amplifier can be backed up to a PC using the USB memory stick connected to the IX Series control panel or PC software. *6 For connection to an IX Series control panel or PC software. The RJ45 connector on the main unit is used for connecting to the expansion unit. *7 When a DL Series device is used. Contact KEYENCE for information on other interfaces. *8 Includes a DL Series communication unit.

Related products

General Purpose Digital Contact Sensor Keyence GT-75AP
Close

Keyence GT-75AP

Read more
General Purpose Digital Contact Sensor Keyence GT-A22L
Close

Keyence GT-A22L

Read more
General Purpose Digital Contact Sensor Keyence GT-76A
Close

Keyence GT-76A

Read more
General Purpose Digital Contact Sensor Keyence GT-H10
Close

Keyence GT-H10

Read more

Keyence is a leading supplier of sensors and instrumentation for a variety of industries. The company offers sensors, measuring systems, vision systems, laser markers, digital microscopes and other products.

Hinter den Kirschkaten 83 DE,
23560, Lübeck, Germany
Phone: +49 (451) 703 64 999
Email: info@sensors-trade.com
2021 All trademarks and images on this site are copyrighted by KEYENCE CORPORATION
Privacy Policy | Cookies Policy | Legal Warning | Imprint | AGB
  • HOME
  • CATALOG
  • ABOUT US
  • CONTACTS
We use cookies to improve your experience on our website. By browsing this website, you agree to our use of cookies.
Accept
Start typing to see products you are looking for.