Sensor Head 150 mm
Keyence IX-150
Image-Based Laser Sensor IX series
Categories: Laser Displacement Sensors, Measurement Sensors
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | IX-150 | |
Reference distance | 150 mm | |
Measuring distance | 100 to 200 mm | |
Detection area | Scan mode | Measuring distance of 100 mm: 56.5 × 42.0 mm (min.) Measuring distance of 150 mm: 82.5 × 61.5 mm (min.) Measuring distance of 200 mm: 108.5 × 81.0 mm (X direction) × (Y direction) *1 |
Line mode | Measuring distance of 100 mm: 56.5 mm (min.) Measuring distance of 150 mm: 82.5 mm (min.) Measuring distance of 200 mm: 108.5 mm (X direction) *1 | |
Laser Light source | Light source | 660 nm (visible light) wavelength red semiconductor laser |
Laser class | Class II laser product (FDA [CDRH] part 1040.10), Class 2 laser product (IEC 60825-1: 2014) | |
Output | 0.95 mW (FDA (CDRH) Part 1040.10), 1.6 mW (IEC 60825-1: 2014) | |
Minimum detectable object size | Scan mode | ø1.7 mm*2 |
Line mode | 1.7 mm × 1.7 mm*2 | |
Repeatability | 50 µm*3 | |
Estimated detection | (Estimated detection: When measuring the height between two points, the minimum step difference is as follows. IX-055: 100 µm / IX-080: 200 µm / IX-150: 500 µm / IX-360: 1000 µm) *3 | |
Sampling cycle | Scan mode | 120 ms (min.) (typical) |
Line mode | 6 ms / 11 ms (selectable) | |
Image receiving element | Monochrome CMOS image sensor | |
Image capture lighting | Light source | Red LED |
Lighting method | Pulse lighting | |
Temperature characteristics | 0.04% of F.S./°C*4 | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent lamp, 5000 lux or less*5 | |
Operating ambient temperature | 0 to +45°C (No freezing) *6 | |
Operating ambient humidity | 35 to 85% RH (No condensation) | |
Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the 3 directions | |
Material | Main unit case: Zinc die-casting / Front cover: Glass, acrylic (hard coat) / Operation indicator cover: TPU / Connector ring: PBT / Connector Zinc die-casting | |
Weight | Approx. 190 g | |
*1 X: Long-side direction of laser, Y: Short-side direction of laser *2 With a correctly attached reference distance. When measuring using the height tool, measurement point min., and no position adjustment in scan mode. When measuring using the height tool, tool window size min., and no position adjustment in line mode. *3 When measuring at the centre of the field of view in scan mode using the “Max.” measurement point of a KEYENCE reference target (white diffuser) at the reference distance. *4 At the reference distance from the target. The F.S. for each model are as follows. IX-055: ±10 mm, IX-080: ±18 mm, IX-150: ±50 mm, IX-360: ±80 mm *5 Using the default settings with a laser light source as the target. *6 With metal mounting. |