Sensor Head, Small Spot
Keyence LK-080
CCD Laser Displacement Sensor LK series
Categories: Laser Displacement Sensors, Measurement Sensors
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | LK-080 | |
Type | Sensor head Standard Sensor head | |
Reference distance | 80 mm (Fine target measurement (focused spot type))76.7 mm (Transparent/mirror target measurement (specular reflection type)) | |
Measuring range | ±15 mm | |
Light source | Type | Red semiconductor laser |
Wavelength | 670nm (Visible light), Class 2 laser product (JIS C6802) | |
Output | 0.95 mW maximum | |
Spot diameter (at standard distance) | Approx. 70 µm | |
Linearity | ±0.1% of F.S. | |
Repeatability | 3 µm*1 | |
Analogue output | Output voltage | ±5 V (3 µm/mV)*2 |
Impedance | 100 ? | |
Output current | 4 to 20 mA (350 ? maximum)*2*3 | |
Alarm output | NPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max. | |
Sampling cycle | 1,024 µs | |
Other functions | Auto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment | |
Temperature characteristics | 0.01% of F.S./°C | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Maximum current consumption | 400 mA max. | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent or fl uorescent lamp: 10,000 lux max. | |
Ambient temperature | 0 to +50 °C (No condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Aluminium die-cast | |
Weight | Approx. 385 g (including cable) | |
*1 Repeatability was obtained using KEYENCE's analogue sensor controller (RD-50) with the number of averaging measurements set to 64. Note: The ripple of the analogue output may be 1 mV or more due to co mmon mode noise when observed with an oscilloscope or a high-speed A/D conversion board. *2 LK-010: When measurements cannot be performed, this is 12 V (21 mA). LK-035/030, LK-085/080, and LK-500: When measurements cannot be performed, this is 12 V (31.2 mA). *3 The ±5 V analog voltage output range (the ± |