Controller
Keyence LK-2011
CCD Laser Displacement Sensor LK series
Categories: Laser Displacement Sensors, Measurement Sensors
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | LK-2011 | |
Type | Amplifier unit, High-precision Controller | |
Measurement mode | ? | |
Reference distance | 30 mm | |
Measuring range | ±5 mm | |
Light source | Type | Visible red semiconductor laser |
Wavelength | 670 nm | |
Output | 0.95 mW | |
Laser Class | FDA (CDRH) 21CFR Part 1040.10 | Class 2 Laser Product |
Laser Class | IEC 60825-1 | |
Spot diameter (at standard distance) | Approx. 30 µm, Approx. 30 x 850 µm | |
Linearity | ±0.1% of F.S. *1 | |
Repeatability | 1 µm*2 | |
Analogue output | Output voltage | ±5 V (1 µm/mV)*3 |
Impedance | 100 ? | |
Output current | 4 to 20 mA (Applicable load: 350 ? max.) | |
Alarm output | NPN: 100 mA max. (40 V max.) (N.C.), Residual voltage: 1 V max. | |
Sampling cycle | 512 µs | |
Other functions | Auto-zero, analog output holding when an alarm occurs, gain switching, response switching, span and shift adjustment of mirror surface measurement mode, changing the sampling cycle | |
Temperature characteristics | 0.01% of F.S./°C | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Maximum current consumption | 400 mA max. | |
Environmental resistance | Enclosure rating | IP67 |
Ambient light | Incandescent or fl uorescent lamp: 10,000 lux max. | |
Ambient temperature | 0 to +50 °C (No condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Polycarbonate | |
Weight | Approx. 515 g (including cable) | |
*1 Linearity was obtained using KEYENCE's standard target (Zirconia block gauge: LK-031/036, LK-081/086, LK-011, White ceramic block gauge: LK-501/503). *2 Repeatability was obtained using KEYENCE's analogue sensor controller (RD-50) with the number of averaging measurements set to 64. Note: The ripple of the analogue output may be 1 mV or more due to co mmon mode noise when observed with an oscilloscope or a high-speed A/D conversion board. *3 When measurement is impossible, 12 V (31.2 mA) is output. |