All-in-one controller, PNP output
Keyence LK-G3000PV
High-speed, High-accuracy CCD Laser Displacement Sensor LK-G3000 series
Categories: Laser Displacement Sensors, Measurement Sensors
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | LK-G3000PV*1 | |
Separate type | LK-G3000P/LK-GD500*2 | |
Type | All-in-one model | |
Head compatibility | All LK-G sensor heads are compatible | |
Connectable number of heads | Maximum of 2 units | |
Display | Minimum display unit | 0.01 µm |
Display range | ±9,999.99 mm to ±9,999.99 µm (Selectable from six levels) | |
Display cycle | 10 times/sec | |
Terminal block | Analogue voltage output | ±10 V x 2 outputs, output impedance: 100 ? |
Analogue current output | 4 to 20 mA x 2 outputs, maximum load resistance: 350 ? | |
Timing input | For OUT1, voltage input | |
Reset input | ||
Auto-zero input | ||
Laser remote interlock input | Non-voltage input | |
Comparator output | For OUT1, PNP open-collector output | |
Alarm output | For OUT1, PNP open-collector output (N.C.) | |
Expansion connector | Timing input | For OUT2, voltage input |
Reset input | ||
Auto-zero input | ||
Program switching input | Voltage input x 3 inputs | |
Laser-Off input | For Head A/Head B, voltage input | |
Comparator output | For OUT2, PNP open-collector output | |
Alarm output | For OUT2, PNP open-collector output (N.C.) | |
Binary | Binary output | Measured data output (21 bits), OUT1/OUT2 selectable, PNP open-collector output |
Strobe output | PNP open-collector output | |
Binary selector output | ||
Binary selector input | Voltage input | |
RS-232C interface | Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable) | |
USB interface | In conformity with USB Revision 2.0 Full speed (USB1.1 compatible) | |
Major functions | 2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO, Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode, ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target, Statistics processing, Connection of setting support software, Selectable head-mounting, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 500 mA or less with 1 head/600 mA or less with 2 heads | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | Approx. 480 g (including the cable) | |
*1 The rating of the PNP open collector: 50 mA max. (30 V max.), residual voltage of 1 V max. The rating of voltage input: 10.2 V or more ON voltage (26.4 V max.) 0.6 mA or less OFF current. *2 LK-G3000P can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W). |