Controller
Keyence LK-G5001
Ultra High-Speed/High-Accuracy Laser Displacement Sensor LK-G5000 series
Categories: Laser Displacement Sensors, Measurement Sensors
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | LK-G5001 | |
Type | Separate type Main controller | |
Sensor head compatibility | Compatible | |
No. of connectable sensor heads | 2 | |
Display | Minimum display unit | 0.001 µm |
Display range | ±999.999 µm to ±9999.99 mm (7 settings selectable) | |
Display cycle | Approx 10 times/sec. | |
Display interface | Display port | Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected |
LED indicator | LASER ON | |
Terminal block | Analogue output voltage | ±10 V output, Output impedance: 100 ?*1 |
Analogue current output | 4 to 20 mA, Maximum load resistance: 350 ?*1 | |
No. of analogue outputs | 2*1 | |
TIMING 1 input | Non-voltage input*2 | |
RESET 1 input | ||
Auto-zero 1 input | ||
Laser remote input | Non-voltage input*1 | |
Alarm output | NPN open-collector output*1 | |
General comparator output | ||
Expansion connector | TIMING input | Non-voltage input*1 |
RESET input | ||
Auto-zero input | ||
Program switching input | ||
Binary selection input | ||
Alarm output | NPN open-collector output*1 | |
Comparator output | ||
Binary output | ||
RS-232C interface | Baud rate: 9600 to 115200 bps Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd | |
USB interface | USB 2.0 Hi-Speed compliant*3 | |
Ethernet interface | 100Base-TX/10Base-T*4 | |
EtherNet/IPTMinterface | Cyclic communication (implicit messaging) Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5 | |
PLC-Link | The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series EtherNet/IPTM, CC-Link, and DeviceNetTM cannot be used in conjunction with PLC-Link | |
Head expansion unit connector | Up to 10 head expansion units can be connected to one main controller | |
Expansion unit connector | Either of the CC-Link unit (LK-CC100) or DeviceNetTM unit (LK-DN100) can be connected | |
Power supply | Power supply voltage | 24 VDC ±10% |
Maximum current consumption | 0.6 A or less with 1 head/3.5 A or less with 12 heads | |
Environmental resistance | Ambient temperature | When one or less head expansion unit is connected: 0 to +50 °C. When two or more head expansion units are connected: 0 to +40 °C. |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | Approx. 600 g | |
*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual. *2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual. This input is applied to all of the synchronised OUT. *3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down. *4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units. *5 The EtherNet/IPTM interface cannot be used when a CC-Link unit or a DeviceNetTM unit is installed. EtherNet/IPTM is supported by the latest controllers. For details on which controllers support EtherNet/IPTM , contact your nearest KEYENCE office. |