Controller PNP Type
Keyence LS-9501P
Ultra-High-speed, High-accuracy Optical Micrometer LS-9000 series
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | LS-9501P*1 | |
Type | Controller: PNP output type | |
No. of connectable sensor heads | 2 | |
Head compatibility | Yes | |
Display | Minimum display unit | 0.01 µm |
Display range | ±99,999.99 µm to ±9,999.9 mm | |
LED display | POWER ON indicator, ERROR indicator | |
Input terminal block | Encoder input | NPN/PNP open-collector output, voltage output (5 V/12 V/24 V), line-driver output |
Synchronous 1, 2 input | Voltage input | |
Auto-zero 1, 2 input | ||
Reset 1, 2 input | ||
Storage trigger input | ||
Storage enable input | ||
Storage data clear input | ||
Statistics 1, 2 input | ||
Statistics clear 1, 2 input | ||
Program selection input | Voltage input x 4 inputs | |
Output terminal | Analogue voltage output | ±10 V x 2 outputs, output impedance 100 ? |
Analogue current output | 4 to 20 mA x 2 outputs, compatible load max. 350 ? | |
Universal output | PNP open-collector output x 10 outputs Measured value and tolerance judgment output, status output allocatable | |
Status 1, 2 output | PNP open-collector output | |
Total judgment output | ||
Memory FULL output | ||
Strobe 1, 2 output | ||
Error output | PNP open-collector output (N.C.) | |
Interface | Ethernet | 1000BASE-T/100BASE-TX*2 |
USB | USB 2.0 HI-SPEED supported (USB 1.1 Full-SPEED compatible)*2 | |
RS-232C | Measured value output, control I/O, setting change, baud rate can be selected up to 115,200 bps | |
Display and settings panel | LS-D1000 Max. four heads connectable | |
Rating | Power voltage | 24 VDC ±10 %, including Ripple (P-P) |
Current consumption | When LS-HA100 not used: 1.0 A max. when 1 head connected; 1.4 A max. when 2 heads connected When LS-HA100 in use: 2.0 A max. when 3 heads connected; 2.3 A max. when 4 heads connected*3 | |
Environmental resistance | Ambient temperature | When LS-HA100 not used: 0 to +50 °C When LS-HA100 in use: 0 to +45 °C |
Relative humidity | 20 to 85 % RH (No condensation) | |
Weight | Approx. 1,500 g | |
*1 PNP open-collector output rating: 50 mA max. (30 V max.), residual voltage of 1 V max. Voltage input rating: Input max. voltage 26.4 V, min. ON voltage 10.8 V, OFF current 0.6 mA max. *2 Sample DLL and LabVIEW programs are available. Contact your local sales office for details. *3 Add the current consumption values for all units when connecting the display settings panel and expansion units. When the LS-9006D or LS-9030D is connected, it counts as two heads. |