Safety Control Unit
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | SL-R11G | |
Response speed FSD1, 2 AUX | 24 ms (including the sensor response speed) | |
Safety light curtain | SL-C Series | |
FSD 1,2 | 230 VAC 4 A 30 VDC 2 A (resistive load)230 VAC 2 A (cos Ø = 0.3) (inductive load)30 VDC 1 A (cos Ø = 0.3) (inductive load) | |
SL-R11 output | Lifespan | Mechanical life: 10 million times min.Electrical life: 100000 times min. |
Response speed when E-STOP is input | 20 ms | |
AUX | 125 VAC 0.5 A 30 VDC 2 A (resistive load)125 VAC 0.25 A (cos Ø = 0.3) (inductive load)30 VDC 1 A (cos Ø = 0.3) (inductive load) | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 150 mA or less (24 VDC, when the SL-R11G is used in a standalone manner) | |
Environmental resistance | Enclosure rating | IP20 (IEC60529) Must be installed within a control panel rated at IP54 or higher. |
Operating ambient temperature | -10 to +55 °C (No freezing) | |
Storage temperature | -10 to +60 °C (No condensation | |
Operating relative humidity | 35 to 85 % RH (No condensation) | |
Storage relative humidity | 35 to 95 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | |
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | |
Material | Polycarbonate | |
Weight | Approx. 380 g |