Application Unit
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
Model | SL-R12EX | ||
Power supply | Supplied by SL-R11 or SL-U2 | ||
Input | Muting input | Maximum input voltage | 26.4 VDC |
Input rating | 24 VDC 2.3 mA | ||
Threshold voltage (ON) | 19 V | ||
Threshold current (OFF) | 0.5 mA | ||
Common ground | A common for A1 and A2, a common for B1 and B2 | ||
Bank selection input | Maximum input voltage | 26.4 VDC | |
Input rating | 24 VDC 1.6 mA | ||
Threshold voltage (ON) | 19 V | ||
Threshold current (OFF) | 0.5 mA | ||
Common ground | A common for A1, A2 and A3, a common for B1, B2 and B3 | ||
Allowance for 2 inputs timing gap | 200 ms max. | ||
Output for muting lamp | 24 VDC 15 mA to 300 mA | ||
Rating | Current consumption | 110 mA or less (including 24 VDC, SL-R12D) | |
Environmental resistance | Enclosure rating | IP20 (IEC60529) Mount in a control panels at least IP54 | |
Ambient temperature | -10 to +55 °C (No freezing) | ||
Relative humidity | 35 to 85 % RH (No condensation) | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Polycarbonate | ||
Weight | Approx. 300 g |