Multi-bank type
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
| Model | SZ-V32*1 | ||
| Type | Multi-bank Type | ||
| Detection capability | Minimum detectable object size | Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting); Reflectance: 1.8% min.; Speed: 1.6 m/s max.*2 | |
| Detectable angle | 190° (-5° to 185°) | ||
| Response time (ON to OFF) | Standard Mode | Scan Cycle A | 160 ms (2 scans) to 1280 ms (16 scans)*3 |
| Scan Cycle B | 168 ms (2 scans) to 1344 ms (16 scans)*3 | ||
| Scan Cycle C | 176 ms (2 scans) to 1408 ms (16 scans)*3 | ||
| High Speed Mode | Scan Cycle A | 80 ms (2 scans) to 640 ms (16 scans)*3 | |
| Scan Cycle B | 84 ms (2 scans) to 672 ms (16 scans)*3 | ||
| Scan Cycle C | 88 ms (2 scans) to 704 ms (16 scans)*3 | ||
| Response time (OFF to ON) | Response time of ON to OFF + 150 ms | ||
| Protection zone | Minimum detectable object size: 70 / 150 mm | Standard Mode: 8.4 m / High Speed Mode: 5.7 m | |
| Minimum detectable object size: 50 mm | Standard Mode: 5.6 m / High Speed Mode: 3.8 m | ||
| Minimum detectable object size: 40 mm | Standard Mode: 4.3 m / High Speed Mode: 2.9 m | ||
| Minimum detectable object size: 30 mm | Standard Mode: 2.9 m / High Speed Mode: 2.0 m | ||
| Minimum detectable object size: 20 mm | Standard Mode: 1.6 m / High Speed Mode: 1.1 m | ||
| Warning zone | Minimum detectable object size: 70 / 150 mm | Standard Mode: 26 m / High Speed Mode: 23 m*4 | |
| Minimum detectable object size: 50 mm | Standard Mode: 25 m / High Speed Mode: 21 m*4 | ||
| Minimum detectable object size: 40 mm | Standard Mode: 24 m / High Speed Mode: 20 m*4 | ||
| Minimum detectable object size: 30 mm | Standard Mode: 23 m / High Speed Mode: 18 m*4 | ||
| Minimum detectable object size: 20 mm | Standard Mode: 21 m / High Speed Mode: 15 m*4 | ||
| Additional safety distance | 100 mm*5 | ||
| Maximum measurement distance | 60 m*6 | ||
| Maximum number of banks | Max. 32 banks | ||
| Multiple scanner heads | Max. 3 | ||
| Camera | -*7 | ||
| Display | QVGA 2.2 inch colour LCD | ||
| Light source | Type, wavelength | Infrared laser diode, 905 nm | |
| Laser class | IEC | Class 1 IEC / EN 60825-1 | |
| FDA | Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice No.50)*8 | ||
| JIS | Class 1 JIS C6802 | ||
| Control output (OSSD output) | Output type | PNP or NPN transistor output (settings configurable with SZ-V Configurator) | |
| Number of outputs | 2 outputs | ||
| Max. load current | 500 mA*9 | ||
| Residual voltage | Max. 2.5 V (with a cable length of 5 m) | ||
| OFF-state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
| Leakage current | Max. 1 mA*10 | ||
| Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
| Load wiring resistance | Max. 2.5 ? | ||
| Input (safety-related) | PNP | ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (EDM input: Approx. 10 mA) | |
| NPN | ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) | ||
| Non safety-related output (AUX output) | Output type | Transistor output (PNP or NPN, settings configurable with SZ-V Configurator) | |
| Number of outputs | 4 outputs | ||
| Max. load current | 50 mA | ||
| Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
| Muting lamp | - | ||
| Interface | USB | USB 2.0 | |
| Ethernet | Standard | - | |
| Transmission rate | |||
| Cable | |||
| Connector | |||
| Networking/data output | |||
| Cable length | Power cable | 30 m or less*11 | |
| Connection cable | 20 m or less each*12 | ||
| Ethernet cable | - | ||
| Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE) |
| EMI | EN55011 Class A, FCC Part15B Class A, ICES-003 Class A | ||
| Safety | IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE), IEC61496-3, EN61496-3 (Type3 AOPDDR), IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2), EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3, UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8 | ||
| Rating | Power consumption | 11.8 W (without load), 55.0 W (with load)*13 | |
| Power voltage | When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less When using a battery: 24 VDC +20 % /-30 % | ||
| Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
| Ambient light | Incandescent lamp: 1,500 lux or less*14 | ||
| Operating ambient temperature | -10 to +50 °C (No freezing) | ||
| Storage temperature | -25 to +60 °C (No freezing) | ||
| Operating relative humidity | 35 to 85 % RH (No condensation) | ||
| Storage relative humidity | 35 to 95 % RH | ||
| Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
| Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
| Material | Scanner head | Main unit case | Magnesium |
| Window | Polycarbonate, PEI | ||
| Indicator part | -*7 | ||
| Display unit | case | Magnesium, PPS, Polycarbonate | |
| System memory | Aluminum, PPE | ||
| Weight | Approx. 2,100 g | ||
| *1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). *2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting. *3 The response time, protection zone, and warning zone are affected by the operation mode. *4 20% or more reflectance is necessary for the minimum detectable object in the warning zone. *5 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance. *6 Even when using the network data output, the maximum measured output distance is 60 m. *7 Only applicable for the type with a camera. *8 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *9 The load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads. *10 Includes when the power is OFF. *11 10 m or less when supplying power from a battery. *12 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads. *13 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation. *14 An ambient light source should not be located within ±5° of the detection plane. |