Amplifier Unit NPN
Keyence AP-40R
Separate Amplifier Type Pressure Sensor AP-40 series
GET A PRICE
To receive a proposal, please send your request to info@sensors-trade.com and specify the required positions and company details.
Specification
| Model | AP-40R | |
| Type | Amplifier Unit, NPN | |
| Applicable sensor head | AP-41, AP-43, AP-44 | |
| Rated pressure | -15% to +110% of F.S. | |
| Display | 3 1/2-digit, 2-colour, 7-segment LED (Character height: 11 mm), Display cycle: 5 times/sec. | |
| Display resolution | AP-41: 0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar AP-43: 0.001 MPa, 0.01 kgf/cm2, 0.2 Psi, 0.01 bar AP-44: 0.2 kPa, 2 mmHg, 0.1 inchHg, 0.002 bar | |
| Display temperature characteristic | ±1.0 % max. of F.S. | |
| Mounting | With supplied mounting bracket (2 types) or optional panel mounting bracket*1 | |
| Response time (Chattering prevention function) | 2.5/5/100/500 msec | |
| I/O | Control output | 100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C. selectable) |
| Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple 10 % or less |
| Current consumption | 105 mA (12 V), 55 mA (24 V) (including sensor head) | |
| Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing) |
| Relative humidity | 35 to 85 % RH (No condensation) | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |
| Shock resistance | 100 m/s2, 3 times in each of X, Y and Z axis | |
| Material | Front case: polyamide, front panel sheet: PET, rear case: polysulfone, cable: oil-proof cabtyre cable | |
| Weight | 80 g (including 2 m cable) (28 g without cable) | |
| *1 Two types of panel mounting brackets are available: OP-31357 (black) and OP-32908 (gray). |